Test and Tag is an essential part of every OH&S system. Electrical safety testing helps protect your employees' safety and helps protect Business from liability. Test and Tag services are created to comply with Australian Standard AS/NZS 3760:2010. Worksafe Victoria is now actively enforcing this requirement. |
|
|
All these inletsand connector are defined by specification IEC 60320. A set of 11 appliance-inlets/connectors are defined in specification AS/NZS 60320.1:2004. We can test the 11 as defined by AS/NZS 60320.1:2004
click here for details.
|
|
Yes, these items need to be tested before being placed in service. Just call GILBERT Australia - we can safely and quickly test the appliance so you can get on with business. |
|
All portable equipment and their associated cables. For example, Power cords, Power boards, Computer equipment, Battery chargers (including Mobile phones), Extension cords, Mircowaves and Kettles. |
|
Yes. 3 phase equipment does need to be tested and tagged according to AS/NZS 3760:2010. The main test to be performed is the earth leakage test. Our equipment can perform this test. |
|
Yes we do. All testing is supplied to you in an electronic database/file. A hardcopy can be arranged if required. |
|
No problem, GILBET Australia keeps all records for Customers for 7 years. Just give us a call and we will fax/email it to you. |
|
No. The standard requires the person to be "Competent". GILBERT Australia has all it's personnel trained in the correct procedures. Furthermore all tests are supervised by qualified Professional Engineers. |
|
The frequency of testing depends on the environment in which the appliance is being used. The harsher the environment then the more likely the appliance is likely to be damaged and the more often it is to be tested. |
|
Yes a RCD needs to be tested and yes Gilbert Australia can test these items. We can perform a standard test to ensure that the RCD trips as per the standard. We can also perform a ramp test if required to see at what point the RCD trips. ALL CD tests are performed using an ISOLATION TRANSFORMER. If your tester does not use an ISO transformer serious consequences may occur. |
|
|
GILBERT Australia - Has the experience and expertise to quickly, safely and efficiently test all your portable equipment to ensure you have piece of mind for your business and your staff working environment. |
|
All testing is done by appointment and we make sure the time is convenient to your work needs. We can do testing after hours (additional costs will apply). If you have an urgent need just call us we will work with you to arrange a suitable time. |